Sequence Controller S2E

Module positions in base unit

Standard configuration

Main base List

This table can be scrolled horizontally.

Main base List
  Slot
PIF PS 0 1 2 3 4 5 6 7 8
BU668 - - CPU IO IO IO IO IO IO IO IO
BU666 - - CPU IO IO IO IO IO  
BU664 - - CPU IO IO IO  

Expansion base List

This table can be scrolled horizontally.

Expansion base List
  Slot
PIF PS 0 1 2 3 4 5 6 7 8
BU668 - - × IO IO IO IO IO IO IO IO
BU666 - - IO IO IO IO IO IO  
BU664 - - IO IO IO IO  

PIF: Slot for expansion interface (IF611)
PS: Slot for power module
0 to 8: Module mounting slots
CPU: Slot for CPU module
IO: Slot for I/O module, transmission module (I/O bus)

Module mounting positions

CPU modules List

This table can be scrolled horizontally.

CPU modules List
  Slot occupancy Mounting slot
BU668 BU666 BU664
PU612E 1 0 0 0
  • *1 Be sure to install the S2E CPU module (PU612E) in the leftmost slot (0).

Expansion I/F modules List

This table can be scrolled horizontally.

Expansion I/F modules List
  Mounting slot
BU668 BU666 BU664
IF661 PIF

Transmission modules List

This table can be scrolled horizontally.

Transmission modules List
  Mounting slot
BU668 BU666 BU664
SN621 1 to 8 0 to 5 0 to 3
SN622 1 to 8 0 to 5 0 to 3
UN611 1 to 8 0 to 5 0 to 3
UN612 1 to 8 0 to 5 0 to 3
DN611A 1 to 8 0 to 5 0 to 3
FL611 1 to 8 0 to 5 0 to 3
FL612 1 to 8 0 to 5 0 to 3
FL654 0 0 0
  • *1 The FL-net remote I/O (FL654) is to be installed in a slot similar to that for the S2E CPU for reasons of unit configuration.

I/O modules List

This table can be scrolled horizontally.

I/O modules List
  Mounting slot
BU668 BU666 BU664
DI632D 1 to 8 0 to 5 0 to 3
DI633 1 to 8 0 to 5 0 to 3
DI653 1 to 8 0 to 5 0 to 3
DI634 1 to 8 0 to 5 0 to 3
DI635 1 to 8 0 to 5 0 to 3
DI635H 1 to 8 0 to 5 0 to 3
IN653 1 to 8 0 to 5 0 to 3
IN663 1 to 8 0 to 5 0 to 3
DO633 1 to 8 0 to 5 0 to 3
DO633P 1 to 8 0 to 5 0 to 3
DO634 1 to 8 0 to 5 0 to 3
DO635 1 to 8 0 to 5 0 to 3
AC663 1 to 8 0 to 5 0 to 3
RO662S 1 to 8 0 to 5 0 to 3
RO663 1 to 8 0 to 5 0 to 3
CD633 (*1) 1 to 8 0 to 5 0 to 3
AD624L 1 to 8 0 to 5 0 to 3
AD634L 1 to 8 0 to 5 0 to 3
AD624 1 to 8 0 to 5 0 to 3
AD674 1 to 8 0 to 5 0 to 3
AD628S 1 to 8 0 to 5 0 to 3
AD638S 1 to 8 0 to 5 0 to 3
AD668 1 to 8 0 to 5 0 to 3
TC618 1 to 8 0 to 5 0 to 3
RT614 1 to 8 0 to 5 0 to 3
DA622L 1 to 8 0 to 5 0 to 3
DA622 1 to 8 0 to 5 0 to 3
DA672 1 to 8 0 to 5 0 to 3
DA664 1 to 8 0 to 5 0 to 3
PI632 (*2) 1 to 8 0 to 5 0 to 3
PI672 (*2) 1 to 8 0 to 5 0 to 3
MC612 1 to 8 0 to 5 0 to 3
MC614 1 to 8 0 to 5 0 to 3
CF611 1 to 8 0 to 5 0 to 3
  • *1 In case of using CD633, install it in the base unit where a CPU module is installed.
  • *2 In case of using the interrupt function of PI632 or PI672, install it in the base unit where a CPU module is installed.