Electromagnetic
Flowmeter
GF642/LF622

Electromagnetic Flowmeter GF642/LF622
General Specificaition
Combined with a multi-functional converter LF622 (Separate type) equipped with its original Noise-suppression Circuit & Advanced Algorithms,The GF642 has a very high tolerance to noise, giving the unit a very stable output even for slurry fluid measurement.
The AF900 Hand-held terminal (HART*1Communicator) can be used for remote control. PROFIBUS-PA*2 or Modbus*3 interface is available as an option.
- *1 HART protocol (Highway Addressable Remote Transducer) is a communication protocol for industrial sensors recommended by the HCF (HART Communication Foundation).
- *2 PROFIBUS is the communication protocol for factory automation and process automation that the PROFIBUS Organization recommends.
Instead of analog control with a conventional analog signal (4-20mA), it is one kind of the fieldbus which digitizes all signals. - *3 Modbus is the communication protocol that Modicon Inc. developed.
Physical layer is RS485.
Main Specifications
Main Specifications List
This table can be scrolled horizontally.
Mounting style | Flange connection type | ||
---|---|---|---|
Meter size |
|
||
Measuring range in terms of flow velocity | 0-0.3m/s to 0-10m/s (0-0.1m/s to 0-0.3m/s as option) | ||
Accuracy | Flow rate | Flow speed of full scale | |
1.0 - 3.28ft/s (0.3 - 1.0m/s) |
3.28 - 32.8ft/s (1.0 - 10m/s) |
||
0 - 100%FS | +/-0.8% FS | +/-0.5% FS | |
Lining materials (Meter size: mm) |
Natural rubber: 500 to 2000mm | ||
Fluid temperature | -10 to +60℃: 500 to 900mm -10 to +40℃: 1000 to 2000mm |
||
Electrode materials | AISI 316L Titanium Hastelloy C equivalent |
||
Grounding ring materials | None | ||
Ambient tempearture | -20 to +60℃ | ||
Structure | IP67 | ||
Power consumption | 10W (14VA) at AC100V and Excitation current: 0.2A | ||
Power supply | AC100V to AC240V, 50/60Hz (Standard) Allowable voltage AC80V to AC264V DC24V (Option) Allowable voltage DC18V to DC36V DC110V (Option) Allowable voltage DC90V to DC130V |