IEC 60076-5 |
Power transformers - Part 5: Ability to withstand short circuit |
IEC 60076-11 |
Power transformers - Part 11: Dry-type transformers |
IEC 60099-4 |
Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
IEC 60099-8 |
Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV |
IEC 60947-1 |
Low-voltage switchgear and controlgear - Part 1: General rules |
IEC 60947-2 |
Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
IEC 61869-1 |
Instrument transformers - Part 1: General requirements |
IEC 62271-1 |
High-voltage switchgear and controlgear - Part 1: Common specifications |
IEC 62271-100 |
High-voltage switchgear and controlgear - Part 100: High-voltage alternating-current circuit-breakers |
IEC 62271-101 |
High-voltage switchgear and controlgear - Part 101: Synthetic testing |
IEC 62271-102 |
High-voltage switchgear and controlgear - Part 102: High-voltage alternating current disconnectors and earthing switches |
IEC 62271-103 |
High-voltage switchgear and controlgear - Part 103: Switches for rated voltages above 1 kV up to and including 52 kV |
IEC 62271-104 |
High-voltage switchgear and controlgear - Part 104: Alternating current switches for rated voltages of 52 kV and above |
IEC 62271-110 |
High-voltage switchgear and controlgear - Part 110: Inductive load switching |
IEC 62271-111 |
High-voltage switchgear and controlgear - Part 111: Automatic circuit reclosers and fault interrupters for alternating current systems up to 38 kV |
IEC 62271-200 |
High-voltage switchgear and controlgear - Part 200: A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
IEC 62271-201 |
High-voltage switchgear and controlgear - Part 201: A.C. insulation-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
IEC 62271-203 |
High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
IEC/TR 62271-310 |
High-voltage switchgear and controlgear - Part 310: Electrical endurance testing for circuit-breakers above a rated voltage of 52 kV |
IEEE Std C37.04 |
Standard Rating Structure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis |
IEEE Std C37.09 |
Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis |
IEEE Std C37.30.1 |
Requirements for AC High-Voltage Air Switches Rated Above 1000 V |
JEC-2200 |
Power transformers |
JEC-2300 |
Alternating current circuit breakers |
JEC-2310 |
Alternating current disconnectors |
JEC-2350 |
Gas insulated switchgear |
JEC-2374 |
Metal oxide surge arrester |
JEC-2390 |
General requirements for high-voltage switchgear and controlgear |
JIS C 4603 |
Alternating current circuit breakers for 6.6kV or 3.3kV |
JIS C 4605 |
Alternating current load break switches for 3.3kV or 6.6kV |
JIS C 4607 |
Alternating current load break switches with tripping device |
JIS C 62271-200 |
A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
JIS E 2501-1 |
Railway applications -Fixed installations- -DC switchgear- Part 1: General |
JIS E 2501-2 |
Railway applications -Fixed installations- -DC switchgear- Part 2: DC circuit-breakers |
JEM 1265 |
Low-voltage metal-enclosed switchgear and controlgear |
JEM 1425 |
A.C. metal-enclosed switchgear and controlgear for rated voltages above 1kV and up to and including 52kV |